Specs at a glance
-
Max. measurement error
Volume flow: +/-0.8% o.r. +/- 0.1% o.f.s
-
Measuring range
up to 750 l/min
-
Medium temperature range
-10 to 70°C (+14 to +158 °F)
Permissible short-term temperature, maximum one hour:
85 °C (185 °F)
Repetition after 4 hours at the earliest -
Max. process pressure
16 bar
-
Wetted materials
PEEK, Stainless Steel, FKM, EPDM
Electrodes: 1.4404/316L
Field of application
Picomag is the economical magmeter for many applications in secondary circuits with conductive liquids in all industries. End customers, skid builders, equipment manufacturers and system integrators value the space-saving Picomag for its flexible installation capabilities. Additionally, its future-oriented, intuitive operation via SmartBlue app on every Bluetooth-enabled smartphone or tablet ensures fast, secure and simple commissioning.
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Ideal for process quality control and monitoring due to temperature and conductivity measurement in utilities.
Device properties
High shock and vibration resistance
Degree of protection: IP65/67
Empty pipe detection
Wireless remote access via Bluetooth SmartBlue app
IO-Link and various I/Os for all line-sizes
1.4" TFT color display with backlight
Benefits
Time-saving, easy configuration even in places difficult to reach – secure Bluetooth connection
Fewer measuring points necessary – simultaneous flow, conductivity and temperature measurement
Cost-efficient specialist for use in tight spaces e.g. skids – sensor and transmitter in one housing
Quick offline configuration check – unique, comfortable knock functionality
Simple device access through its whole lifecycle – no manual needed due to intuitive SmartBlue App
Instant local process monitoring – large, user-friendly display of all measurement activities
Flexible integration into all fieldbus systems – plug-and-play device with IO-Link
Videos
Fundamental selection
-
Simple products
- Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Competence Brochure (CP)
Picomag – pocket-sized plug-and-play flowmeter for utilities (e-book – PC version)
English version - 11/2022
e-book: Check out this electromagnetic plug-and-play flowmeter for your Utility application, and easily acces related tools such as the SmartBlue App, movies or brochures.
Language:
English
Version:
15/11/2022
File size:
20 MB
File name:
CP01318DEN_0422_PC.pdf
-
-
-
Operating Instruction (BA)
BA Picomag IO-Link
English version - 08/2023
Electromagnetic flowmeter
EN 01/08/202301/04/202201/05/202002/09/201901/03/2018Language:
English
Version:
01/08/2023
File size:
2.1 MB
File name:
BA01697DEN_0723-00.pdf
-
-
-
Operating Instruction (BA)
BA Picomag IO-Link
Electromagnetic flowmeter
EN 01/08/202301/04/202201/05/202002/09/201901/03/2018Language:
English
Version:
01/08/2023
File size:
2.1 MB
File name:
BA01697DEN_0723-00.pdf
-
-
-
Special Documentation (SD)
UKCA marking
Flow, density, concentration, viscosity
EN 04/11/202201/10/2021Language:
English
Version:
04/11/2022
File size:
357.4 KB
File name:
SD02752DEN_0222-00.pdf
-
-
-
Special Documentation (SD)
SD DIN SPEC 91406
Automatic identification of physical objects
EN 17/05/202431/03/202401/12/202101/11/2021Language:
English
Version:
17/05/2024
File size:
649.4 KB
File name:
SD02825DEN_0424-00.pdf
-
-
-
Special Documentation (SD)
Picomag Basic Safety Instructions Associated documentation: BA01697D
Basic Safety Instructions
Language:
English
Version:
01/09/2017
File size:
359.5 KB
File name:
SD01949DEN_0117.pdf
-
-
-
Manufacturer Information (MI)
Proline Picomag Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Picomag IO-Link: 1.01.01EN 13/11/2019Language:
English
Version:
13/11/2019
File size:
62.9 KB
File name:
MI01456D06EN01.19.pdf
-
-
-
Competence Brochure (CP)
Picomag – pocket-sized plug-and-play flowmeter for utilities (e-book – Tablet version)
e-book: Check out this electromagnetic plug-and-play flowmeter
for your utilityapplication, and easily acces related tools such as
the SmartBlue App, movies or brochures.Language:
English
Version:
15/11/2022
File size:
6 MB
File name:
CP01318DEN_0422_epub.epub
-
-
-
Competence Brochure (CP)
Picomag - Le débitmètre plug-and-play intelligent pour les utilités (eBook – Version PC)
eBook: Essayez ce débitmètre électromagnétique plug-and-play pour vos
applications
dans les utilités, et accédez facilement à tous les outils tels que
l'application SmartBlue,
les vidéos et les brochures.Language:
French
Version:
14/03/2019
File size:
5.8 MB
File name:
CP01318DFR_0319_PC.pdf
-
-
-
Competence Brochure (CP)
Picomag – pocket-sized plug-and-play flowmeter for utilities (e-book – PC version)
e-book: Check out this electromagnetic plug-and-play flowmeter for
your Utility application, and easily acces related tools such
as the SmartBlue App, movies or brochures.Language:
English
Version:
15/11/2022
File size:
20 MB
File name:
CP01318DEN_0422_PC.pdf
-
-
-
Case Study (CS)
Picomag - Höchste Funktionalität bei gleichzeitig kompaktem Design
Höchste Funktionalität bei gleichzeitig kompaktem Design. Die Firma
Ehrmann AG
vertraut dem Picomag von Endress+HauserLanguage:
German
Version:
01/01/2019
File size:
975 KB
File name:
CS01582B99DE0119_Ehrmann_SCREEN.pdf
-
-
-
Case Study (CS)
Energieeffizienzoptimierung
Erfassung und Analyse des Heiz-
wärmebedarfsim Schulhaus
EttingenLanguage:
German
Version:
02/08/2021
File size:
935.6 KB
File name:
CS01710S_20_DE0120_Gemeinde_Ettingen.pdf
-